歡迎來到 中山日月(yue)明電氣(qi)設備有限公司 企業官網(wang)
服務支持: / /
86系列插(cha)座箱:
GCK系(xi)(xi)(xi)列(lie)開關柜適用于工(gong)(gong)礦(kuang)企業(ye),三相(xiang)交(jiao)流(liu)頻率50HZ、額定電(dian)(dian)壓380V至600V,電(dian)(dian)力系(xi)(xi)(xi)統的(de)(de)(de)一次。配電(dian)(dian)和以異步電(dian)(dian)動(dong)機(ji)為主要控(kong)(kong)制(zhi)對象的(de)(de)(de)二次配電(dian)(dian)或控(kong)(kong)制(zhi)設備,亦適用于車站、碼(ma)頭、高層建筑(zhu),尤(you)其適用于發電(dian)(dian)廠、變電(dian)(dian)站、石(shi)油、化工(gong)(gong)、冶金(jin)、機(ji)械、輕(qing)工(gong)(gong)生產(chan)線的(de)(de)(de)電(dian)(dian)動(dong)機(ji)的(de)(de)(de)群(qun)控(kong)(kong)系(xi)(xi)(xi)統和現場(chang)控(kong)(kong)制(zhi)裝置,如配以適當(dang)的(de)(de)(de)接口(kou)還可以與PC (程序控(kong)(kong)制(zhi)器)或微機(ji)處理(li)器組成供配電(dian)(dian)自動(dong)控(kong)(kong)制(zhi)系(xi)(xi)(xi)統。
結構(gou)特(te)點:
控制柜的主要特點是能夠靈活地根據所需的各單元線路線方案進行任意組合,且一旦發生故障時,可以在很短時間內將單元抽出,換上備用單元繼續使用,相同單元可在任一-柜上互換。單元隔空設置通風道,柜頂上設有壓力釋放裝置,用于釋放配電柜內部故障時產生的高壓游離氣體。
基本電氣參數:
1.額定絕緣電(dian)壓(ya)交(jiao)流 380V
2、額定工作電(dian)壓交流 660V
3、控制電動機容量 300KW
4、機械(xie)壽命(次) 500
5、額定工作電(dian)流: (A)
水平母線:1600、2000、2500、3150、4000
垂直母線:400、 630、 800、 1000、 1250、1600
受電電路:1000、 1600、2000、2500、 3150、4000
饋電電路電流:630
一次接插件:100、160、 250、 400
二次插件:15
6、額定短時(shi)耐受電(dian)流 (ls)
有效值KA/s30、50、80
峰(feng)值KA 105
7、耐(nai)壓V/1min 2500
8、分斷能力(Ka)30、 50、80
的(de)開(kai)(kai)關柜具有一般的(de)控(kong)制保護(hu)功能(neng),相線(xian)和(he)中性線(xian)可同時(shi)斷開(kai)(kai)或(huo)連接(jie)。符合安全功耗(hao)和(he)維護(hu)規范(fan)。配電(dian)(dian)部分根據配電(dian)(dian)原(yuan)理和(he)功耗(hao)屬性進行(xing)配置。可分為照明,空調插(cha)(cha)座(zuo)(zuo),計(ji)算機插(cha)(cha)座(zuo)(zuo),通用(yong)電(dian)(dian)源插(cha)(cha)座(zuo)(zuo),廚(chu)房插(cha)(cha)座(zuo)(zuo),浴室插(cha)(cha)座(zuo)(zuo)和(he)其(qi)他配電(dian)(dian)電(dian)(dian)路(lu)(lu)(lu),以防止和(he)防止由于電(dian)(dian)路(lu)(lu)(lu)過(guo)載,電(dian)(dian)氣(qi)火災而引起(qi)的(de)線(xian)路(lu)(lu)(lu)老化電(dian)(dian)路(lu)(lu)(lu)中的(de)電(dian)(dian)氣(qi)裝(zhuang)置發生故障的(de)現象并影響(xiang)其(qi)他電(dian)(dian)氣(qi)設備的(de)正常運(yun)行(xing)。同時(shi),它(ta)也適用(yong)于維護(hu)。在配電(dian)(dian)電(dian)(dian)路(lu)(lu)(lu)中設置了具有遠程(cheng)開(kai)(kai)關功能(neng)的(de)繼(ji)電(dian)(dian)器(qi)。該(gai)繼(ji)電(dian)(dian)器(qi)使用(yong)電(dian)(dian)磁(ci)聯(lian)鎖繼(ji)電(dian)(dian)器(qi)或(huo)靜(jing)態繼(ji)電(dian)(dian)器(qi),能(neng)耗(hao)低(di)。無能(neng)耗(hao)繼(ji)電(dian)(dian)器(qi)。
抽屜式配電柜:抽屜式配電柜是安全的配電設備之一。它由鋼板制成。櫥柜配有抽屜。每個電氣組件都安裝在抽屜中以形成獨立的功能。單元。抽屜式配電柜的可靠性,互換性和安全性高于上述兩個配電柜。適(shi)用(yong)(yong)(yong)于(yu)需要高(gao)可靠性電(dian)(dian)源(yuan)的集中(zhong)控(kong)制(zhi)配(pei)電(dian)(dian)中(zhong)心。電(dian)(dian)源(yuan)照明(ming)配(pei)電(dian)(dian)柜(ju):電(dian)(dian)源(yuan)照明(ming)配(pei)電(dian)(dian)柜(ju)使用(yong)(yong)(yong)封閉(bi)的設備,安(an)全級別(bie)根據應用(yong)(yong)(yong)程序的要求而變化。配(pei)電(dian)(dian)柜(ju)主(zhu)要用(yong)(yong)(yong)于(yu)低電(dian)(dian)平配(pei)電(dian)(dian)設備,例如B.用(yong)(yong)(yong)于(yu)工礦企業生產現場的配(pei)電(dian)(dian)控(kong)制(zhi)。
高(gao)壓(ya)(ya)環網(wang)柜通(tong)常分(fen)為(wei)(wei)三種類(lei)型:空氣邊緣,全邊緣和(he)SF6邊緣。它們用于切換(huan)負載電(dian)(dian)流(liu),中(zhong)斷變壓(ya)(ya)器(qi)的(de)短路(lu)電(dian)(dian)流(liu)和(he)開路(lu)電(dian)(dian)流(liu),以及在一定距離上(shang)控(kong)制和(he)保(bao)護架空線(xian)和(he)電(dian)(dian)纜線(xian)的(de)充電(dian)(dian)電(dian)(dian)流(liu)。它是環形網(wang)絡和(he)終(zhong)端電(dian)(dian)源的(de)重要交(jiao)換(huan)設備。在機柜中(zhong),氣動(dong)負載開關主要是產氣,壓(ya)(ya)縮(suo)和(he)真(zhen)空開關。邊緣為(wei)(wei)SF6的(de)負載開關為(wei)(wei)SF6類(lei)型。由于SF6氣體封閉在外殼中(zhong),因此看不到它形成(cheng)的(de)隔(ge)板。
環形網(wang)絡機柜中的負(fu)載開(kai)(kai)(kai)關(guan)通常(chang)需要三個位置,即關(guan)閉負(fu)載,斷開(kai)(kai)(kai)電路連接和(he)接地。氣體發生,壓(ya)縮和(he)SF6負(fu)載開(kai)(kai)(kai)關(guan)可在三個位置輕松(song)觸及,而(er)真空滅弧型只(zhi)能打開(kai)(kai)(kai)且不能隔(ge)(ge)離(li)。因此,增加了在負(fu)載開(kai)(kai)(kai)關(guan)前(qian)面帶有(you)隔(ge)(ge)離(li)開(kai)(kai)(kai)關(guan)的常(chang)規真空負(fu)載環網(wang)開(kai)(kai)(kai)關(guan)設備(bei)。形成隔(ge)(ge)離(li)裂縫。